The OpenNET Project / Index page

[ новости /+++ | форум | теги | ]

Интерактивная система просмотра системных руководств (man-ов)

 ТемаНаборКатегория 
 
 [Cписок руководств | Печать]

mlxcontrol (8)
  • >> mlxcontrol (8) ( FreeBSD man: Команды системного администрирования )

  • BSD mandoc
     

    NAME

    
    
    mlxcontrol
    
     - Mylex DAC-family RAID management utility
    
     
    

    SYNOPSIS

    Aq command [args]
    status [-qv ] [drive ]
    rescan controller [controller ... ]
    detach drive [drive ... ]
    detach -a
    check drive
    config controller
    help command  

    DESCRIPTION

    The utility provides status monitoring and management functions for devices attached to the mlx(4) driver.

    Controller names are of the form "mlxN" where N is the unit number of the controller. Drive names are of the form "mlxdN" where N is the unit number of the drive. Do not specify the path to a device node.

    status
    Print the status of controllers and system drives. If one or more drives are specified, only print information about these drives, otherwise print information about all controllers and drives in the system. With the -v flag, display much more verbose information. With the -q flag, do not print any output. This command returns 0 if all drives tested are online, 1 if one or more drives are critical and 2 if one or more are offline.
    rescan
    Rescan one or more controllers for non-attached system drives (e.g. drives that have been detached or created subsequent to driver initialisation). If the -a flag is supplied, rescan all controllers in the system.
    detach
    Detach one or more system drives. Drives must be unmounted and not opened by any other utility for this command to succeed. If the -a flag is supplied, detach all system drives from the nominated controller.
    check
    Initiate a consistency check and repair pass on a redundant system drive (e.g. RAID1 or RAID5). The controller will scan the system drive and repair any inconsistencies. This command returns immediately; use the status command to monitor the progress of the check.
    rebuild
    Requires two arguments, controller and physdrive as specified in the output of the status command. All system drives using space on the physical drive physdrive are rebuilt, reconstructing all data on the drive. Note that each controller can only perform one rebuild at a time. This command returns immediately; use the status command to monitor the progress of the rebuild.
    config
    Print the current configuration from the nominated controller. This command will be updated to allow addition/deletion of system drives from a configuration in a future release.
    help
    Print usage information for command

     

    AUTHORS

    The mlxcontrol utility was written by An Michael Smith Aq msmith@FreeBSD.org .  

    BUGS

    The config command does not yet support modifying system drive configuration.

    Error log extraction is not yet supported.


     

    Index

    NAME
    SYNOPSIS
    DESCRIPTION
    AUTHORS
    BUGS


    Поиск по тексту MAN-ов: 




    Партнёры:
    PostgresPro
    Inferno Solutions
    Hosting by Hoster.ru
    Хостинг:

    Закладки на сайте
    Проследить за страницей
    Created 1996-2024 by Maxim Chirkov
    Добавить, Поддержать, Вебмастеру